Article in HTML

Author(s): Shraddha Chauhan, Lata Sheo Bachan Upadhyay*

Email(s): contactlataupadhyay@gmail.com

Address: National Institute of Technology Raipur, Department of Biotechnology, Raipur, Chhattisgarh, 492010
*Corresponding author: contactlataupadhyay@gmail.com

Published In:   Volume - 32,      Issue - 1,     Year - 2019


Cite this article:
Chauhan and Upadhyay (2019). Development and fabrication of a paper based analytical device using iron oxide nanoparticles to detect arsenic in aqueous samples. Journal of Ravishankar University (Part-B: Science), 32 (1), pp. 23-26.https://doi.org/10.52228/JRUB.2019-32-1-5



Journal of Ravishankar University –B, 32 (1), 23-26 (2019)

 Development and fabrication of a paper based analytical device using iron oxide nanoparticles to detect arsenic in aqueous samples

                        Shraddha Chauhan, Lata Sheo Bachan Upadhyay*

                                National Institute of Technology Raipur, Department of Biotechnology, Raipur, Chhattisgarh, 492010

                                *Corresponding author: contactlataupadhyay@gmail.com

[Received: 30 January 2019; Revised version: 05 March 2019; Accepted: 12 March 2019] 

Abstract. Ground water arsenic contamination is one of the major global issues in recent days. The long exposure of arsenic can cause hazardous health effects like skin cancer, lung cancer as well as heart diseases. Conventional methods for monitoring arsenic level is often strenuous and require highly skilled personals to perform the measurements, thus there is a need to develop a simple and cost- effective techniques for quick and continuous monitoring. Paper-based approach for detecting the arsenic is a low-cost, non-instrumental method and provides on-site detection of water contaminants. In this study a rapid, simple and affordable method for arsenic detection was developed. This methodology involves the generation of arsine gas inside the analysis system that reacts with the silver nitrate present on the paper analytical device (PAD). This reaction between silver nitrate and arsine gives a colored product that was detected by scanning the colored intensity with image processing software. The iron oxide nanoparticles act as a reducing agent that causes the generation of arsine gas from arsenic. These nanoparticles were synthesized through green technology by using henna extract. The whole reaction takes place in the glass vial with the rubber cap on it at which the PAD was placed. Experimental parameters like concentration of reducing agent, silver nitrate and reaction time were evaluated that affects the performance of the analytical process. Under optimal conditions the method showed the detection limit of 0.005ppm.

Keywords: arsenic, nanoparticles, iron oxide nanoparticles, paper analytical device.

Introduction

Arsenic poisoning in the water is a major issue in recent year not in India as well as in many other countries including Bangladesh, China and USA [Smith et al., 2000]. The arsenic consumption can lead to severe diseases that leads to arsenicosis, cancer, skin lesion etc. Thus the detection of arsenic in water samples is a necessary need of time. The arsenic is a color less and odor less compound so this makes the detection of arsenic more complicated. Various detection methods including chromatographic, atomic absorption are being utilize for the detection of arsenic. But these methods are complicated, time consuming and costly to utilize for general use as well as it lacks onsite detection. Therefore there is need to design a device that can be utilize for onsite detection and can provide specific results in less time and can be maintained easily. Recently paper based devices has gain much attention for on-site detection of analytes. Stocker et al. has developed an E. coli based paper device for arsenic detection that shows the maximum detection level up to 8 µg/L[Stocker et al., 2003]. Many other biosensors that includes gold nanoparticles were also developed but gold nanoparticles tend to generate color change in the presence of every analyte so this lacks the specificity of the sensor for any particulate analyte detection. Therefore the development of such small device that can give instant result and should have high specificity is the need of time [Chowdury et al., 2017]. In this study a device was developed that incorporates paper substrate that makes it economic as well as easy to handle and simultaneously it is very specific towards arsenic only.

Materials and methods

Materials

Arsenic trioxide (As2O3), silver nitrate (AgNO3), Ferrous sulphate (FeSO4) hydrochloric acid (HCl), Sulfuric acid (H2SO4) hydrogen peroxide (H2O2) and sodium hydroxide (NaOH), Deionized water (MQ) from Milipore® (Merck KGaA Darmstadt, Germany) Whatman No. 1 (Whatman (GE Healthcare Life science). 2 mL glass vials from borosil. Henna was collected from NIT garden. All the chemical were from Loba Chemie (Mumbai).

Synthesis of iron oxide nanoparticles

Iron oxide nanoparticles that were used as a reducing agent in this process, has reported to have strong reducing ability. To synthesis iron oxide nanoparticles from henna, 5 gm of henna leaves were washed, dried and grinded into powder. This powder was further used to prepare the extract of henna by mixing it in distilled water and boiled the solution for 10 minutes. The solution was filtered with Whatman filter paper No.1. The henna extract was mixed with FeSO4 (0.02M) in equal volumetric ratio and placed at 60°C and the pH was maintained at 11. The synthesized iron oxide nanoparticles were characterized for their morphology by scanning electron microscopy (SEM).

Experimental Procedure


shaken to provide the proper mixing to the solution. The addition of iron oxide nanoparticles reduces the arsenic into arsine. Arsine which is a gas reacted with the silver nitrate on the paper substrate and form a colored complex of arsine and silver nitrate [Pena-Pereira et al., 2018]. This colored complex is the measure of the amount of arsenic present in the sample. To determine the quantity of arsenic the PAD was subjected to image processing via image J software. The figure 1 shows the vials arranged for the sample analysis.

Figure 1. Experimental setup for analysis of arsenic

To design the paper substrate the method reported by [Chauhan et al., 2012] was followed. The paper was cut circularly in a 1cm diameter size and the then dipped into the silver nitrate solution (5%) for 1minute [Nie et al., 2012]. The paper substrate was then removed from the solution and dried in dark condition. The empty vials were thoroughly washed to remove impurities and then autoclaved. The paper substrate with silver nitrate was placed in the vials at screw hole cap over a PTEF faced septum, that act as a recognition element. The arsenic sample (0.5 mL) was placed in the vial and further the 0.7mL reducing agent (iron oxide nanoparticles) was injected into the vial, the vials were gently shakes.

Result and discussion

Characterization of iron oxide nanoparticles

The primary detection was visualized through the color change of the solution [Saif et al., 2016]. The addition of henna extract reduces the FeSO4 into iron oxide nanoparticles, which can be seen by the change occurred in the solution from reddish brown to black (figure2). Further analyzation the morphology of the iron oxide nanoparticles the powdered sample of iron oxide nanoparticles was studied under SEM. The results displayed in the SEM images (figure 3) showed that the nanoparticles are spherical and agglomerated.

                                                                

Figure 2.  Color change of iron oxide nanoparticals from reddish brown to black

 

Figure 3. SEM image of iron oxide nanoparticals

 

Evaluation of experimental parameters and analysis of color mode

The parameters i.e. amount of silver nitrate, iron oxide nanoparticles were evaluated by checking the variation in the experimental parameters. To optimize the concentration of silver nitrate experiment was conducted by varying the amount of silver nitrate from 0.5 mg to 7.5 mg. The results in a form of color intensity of the PAD displayed that 5.5 mg of silver nitrate gives better detection in terms of mean intensity (figure 4)

 

80

 

60

 

40

 

20

 

0

0.5

1.5

3.5

Silver nitrate (%)

5.5

7.7

 

 

 

 


Text Box: Mean intensity

 

 

 

 

 

 

 

 

 

 

 

Figure 4. Mean intensities at different concentration of silver nitrate

 

Further the amount of iron oxide nanoparticles was also optimized by varying the concentration of nanoparticle from 0.1mL to 0.9mL and keeping the silver nitrate concentration constant at 5.5 mg. The graph of a mean intensity displayed that 0.7mL is the optimum concentration for the procedure (figure 5).

 

 

 

 

 

 

 

 

 

Text Box: Mean intensity

Volume of reducing agent (mL)

0.9

0.7

0.5

0.3

0.1

0

140

 

120

 

100

 

80

 

60

 

40

 

20

 

0

 

 

 

 

 

 

 

 


                             

 

Figure 5. Graph of a response against different volumes of reducing agent

 

After every optimization steps the colored complex of silver nitrate and arsine was evaluated by image processing software called ImageJ. In which the digital image of PAD was assigned by a numerical value called mean intensity. These mean intensities at every step was recorded and used for analyzing the parameters as well as the arsenic concentration.

Analysis of real arsenic sample

The procedure was used to detect the arsenic in real water samples. For the detection of arsenic the samples were collected from campus pond of NIT Raipur. Simultaneously the samples were also investigated from atomic absorption spectroscopy (AAS). No significant difference was observed in both the results. There was no substance of arsenic was recorded in the samples. To validate the procedure artificial arsenic samples were tested and the device as found to be sensitive for very minimum amount of arsenic i.e 0.005 ppm. This limit is lower than the set standard of WHO for arsenic i.e. 10 ppb.

Conclusion

This work describes the easy method for arsenic analysis. This study describes the interaction between silver nitrate and arsine gas that gives the visual colorimetric detection of the amount of arsenic. In this method iron oxide nanoparticles were used for the arsenic detection that is not done in previous studies this increase the novelty of the work. This process is very sensitive towards the arsenic concentration that it can detect very minimal amount present in the sample.

References

Chauhan, S. and Upadhyay, L.S.B. (2018). An efficient protocol to use iron oxide nanoparticles in microfluidic paper device for arsenic detection. MethodsX, 5: 1528-1533.

Chowdury, M.A., Walji, N., Mahmud, M.A. and MacDonald, B.D. (2017). Paper based Microfluidic Device with a Gold Nanosensor to Detect Arsenic Contamination of  Groundwater  in  Bangladesh. Micromachines, 8: 71.

Nie, J., Zhang, Y., Lin, L. Li, C., Zhou, S., Zhang, L. and Li, J. (2012). Low-cost fabrication of paper-based microfluidic devices by one-step plotting. Anal. Chem. 84: 6331-6335.

Saif, S., Tahir, A. and Chen, Y. (2016). Green synthesis of iron nanoparticles and their environmental applications and implications. Nanomaterials,6:209.

Smith, A.H., Lingas E.O., and Rahman, M. (2000). Contamination of drinking-water by arsenic in Bangladesh: a public health emergency. Bulletin of the World Health Organization 78: 1093- 1103.

Stocker, J., Balluch, D., Gsell, M., Harms, H., Feliciano, J., Daunert, S., Malik, K.A. and Van der Meer, J.R. (2003). Development of a set of simple bacterial biosensors for quantitative and rapid measurements of arsenite and arsenate in potable water, Environ. Sci. Technol. 37:4743- 4750.



Related Images:

Recomonded Articles:

Author(s): Sonam Patel; Afreen Anjum; Veenu Joshi; Afaque Quraishi

DOI: 10.52228/JRUB.2024-37-1-4         Access: Open Access Read More

Author(s): Richa Tembekar; Kallol K. Ghosh; Angel Minj; Abhishek Katendra

DOI: 10.52228/JRUB.2024-37-2-15         Access: Open Access Read More

Author(s): Sahdev; Tomeshwar; Kuldeep

DOI: 10.52228/JRUB.2024-37-2-16         Access: Open Access Read More

Author(s): Deepali Nagre; Roseline Xalxo; Vibhuti Chandrakar; S. Keshavkant

DOI: DOI: 10.52228/JRUB.2021-34-1-10         Access: Open Access Read More

Author(s): Beeta Rani Khalkho; Anushree Saha; Bhuneshwari Sahu; Manas Kanti Deb*

DOI: 10.52228/JRUB.2021-34-1-6         Access: Open Access Read More

Author(s): Nikita Verma; Swarnlata Saraf

DOI:         Access: Open Access Read More

Author(s): Taranjeet Kukreja; Arushi Saloki; Swarnlata Saraf

DOI: 10.52228/JRUB.2024-37-1-3         Access: Open Access Read More

Author(s): Pritimala Sahu; Bhanushree Gupta

DOI: 10.52228/JRUB.2024-37-2-12         Access: Open Access Read More

Author(s): Shweta Sao; Hemlata Nishad

DOI:         Access: Open Access Read More

Author(s): N Shweta; Sneha Kulbhaje; S Keshavkant

DOI:         Access: Open Access Read More

Author(s): Renu Bhatt; Neha Pandey

DOI:         Access: Open Access Read More